기기명 (Instrument) : Sound Level Meter
제작회사 (Manufacturer) : BENETECH
형식 (Model) : GM1352
세부내용 (Description) :
About the product
1. Small and portable
2. Can be used for measurement of noise engineering, quality control, health prevention and environmental noise
3. Suitable for factories, offices, families, and etc
4. Powered by 3 x 1.5V AAA batteries
Features
1. Measuring range: 30-130 dBA
2. Accuracy: +-1.5dB
3. Frequency response: 31.5Hz-8000Hz
4. Frequency weighting feature: A weighting
5. Resolution: 0.1dB
6. Operating temperature: 0 - 40 celsius degree, 10%-80% relative humidity
7. Storage temperature: -20 - 60 celsius degree, 0-90% relative humidity
8. Min/Max/lock current value
9. LCD backlight
10. Manual/auto power off
Specification:
General |
Model |
GM1352 |
Size |
155.6*49.6*26.6mm |
|
Weight |
82g |
|
Package Weight |
One Package Weight |
0.16kgs / 0.34lb |
Qty per Carton |
20 |
|
Carton Weight |
4.00kgs / 8.82lb |
|
Carton Size |
53cm * 33cm * 23cm / 20.87inch * 12.99inch * 9.06inch |
|
Loading Container |
20GP: 662 cartons * 20 pcs = 13240 pcs |
첨부 (Attach)
파일내용 (The content of file) :
-. Instruction Manual (사용설명서) :
사진 (Picture) :
'사용설명서' 카테고리의 다른 글
Tektronix / TBS1000 series_디지털 스토리지 오실로스코프 (0) | 2020.07.23 |
---|---|
B&K (Brüel & Kjær) / 2250_SOUND LEVEL METER / ANALYZER (0) | 2020.07.23 |
YOKOGAWA / 2558A_AC Voltage Current Standard (0) | 2020.07.22 |
Tektronix / TDS1000 and TDS2000 Series_Oscilloscopes (0) | 2020.07.22 |
EZ Digital(LG) / FG-7005C_Sweep / Function Generator (0) | 2020.07.21 |
기기명 (Instrument) : AC Voltage Current Standard (교류 전압 전류 교정기)
제작회사 (Manufacturer) : YOKOGAWA (요꼬가와)
형식 (Model) : 2558A
세부내용 (Description) :
The 2558A is a cost-effective, high-precision instrument capable of outputting a wide range of AC voltages and currents for the calibration of AC measurement devices such as analog wattmeters, power meters, clamp-on testers, and current transformers. Intuitive front panel controls and various computer interfaces enable the 2558A to be operated manually or become integrated into an larger system.
FEATURES
The 2558A AC Voltage Current Standard offers users the best-in-class functionality and reliability customers have come to trust from Yokogawa.
A suite of features for verification and testing of AC measuring devices
· Voltage, Current, and Frequency sweeping
· Output Divider
· Direct Readout of the Deviation
· Digital Display of Output
· Common Current Output Terminals
Go beyond conventional accuracy and output standards
The wide output ranges of 1.00 mV to 1200.0 V AC and 1.00 mA to 60.00 A AC mean that the 2558A is the instrument of choice for the cost effective calibration of AC analog meters. Rotary controls and a range of computer interfaces enable the 2558A to be intuitively operated through the frontpanel or controlled by an ATE system.
High Accuracy
AC Voltage: +/- 0.04 %
AC Current: +/- 0.05 %
The 2558A AC Voltage Current Standard is more than sufficient to calibrate meters with a class 0.1 % accuracy.
10 to 120 % of range |
|||
+/- (% of setting + % of range) |
|||
|
50/60 Hz |
40 ≤ f ≤ 400 Hz |
400 |
AC Voltage |
0.03 + 0.01* |
0.05 + 0.01 |
0.10 + 0.02 |
AC Current |
0.04 + 0.01* |
0.06 + 0.01 |
0.12 + 0.02 |
* Add 0.1% of range when output is 120% to 144%.
1 to 10% of range |
|||
+/- (% of range) |
|||
|
50/60 Hz |
40 ≤ f ≤ 400 Hz |
400 |
AC Voltage |
0.013 |
0.015 |
0.03 |
AC Current |
0.014 |
0.016 |
0.032 |
High Stability
AC Voltage/Current: +/- 50 ppm/h
+/- (20 ppm of range + 30 ppm of range)/h
Perform measurements with high repeatability over time
Wide Output Range
AC Voltage: 1.00 mV to 1200.0 V
AC Current: 1.00 mA to 60.00 A
6 voltage ranges (100 m/1/10/100/300/1000 ([V]))
4 current ranges (100 m/1/10/50 ([A]))
The generation range is 0 to 144 % of range
Wide Frequency Range
40 to 1000 Hz (Frequency accuracy: +/- 50 ppm)
The 2558A provides fixed frequencies of 50/60 Hz (commercial) and 400 Hz (marine and aviation), as well as variable frequencies from 40 to 1000 Hz.
The high frequency accuracy of the 2558A (50 ppm) also enables it to be used to calibrate frequency meters.
Multiple 2558A units can be synchronized using the internal phase shifter. This means that two 2558As can be used as accurate sources of voltage and current for calibrating power meters.
APPLICATION
Calibration & Meter Testing
The 2558A provides specific functions to enable meters to be calibrated accurately and efficiently.
Using the output divider and deviation
Calibrating two or more points is quick and simple. It is only necessary to preselect the number of required calibration points with the lower divider control and then use the upper control to step the output to the next calibration point. The deviation settings will then enable the output value and error of each calibration point to be displayed directly.
The deviation preset control can be used to move the output value in small increments (2 or 5 % of the step between calibration points).
This means that it is possible to finely approach the target calibration point, either from a lower value or a higher one, without exceeding it. This is particularly useful when the friction (hysteresis) of the moving part needs to be taken into consideration. In this case, the point is calibrated twice, once from a lower value and once more from a higher value and the final calibration result is the average of the two.
Using sweep
Needle sticking tests can be performed with high repeatability. It is possible to stop at any point and sweep around it in fine detail.
Power Calibration
A power calibration system can be created by using two 2558As (one each for AC voltage and AC current) together with a Yokogawa WT3000 power analyzer as the reference.
One of the 2558As acts as the master unit and provides the synchronizing oscillator signal. The required power factors is set by adjusting the phase shifter on the slave unit and monitoring the result on the WT3000. A 3 phase power calibrator system can be simply built by adding further 2558As.
Higher Current Output
To generate higher current than 72 A, two 2558As can be connected to double the output to 144 A.
Condition:
· Accuracy, stability, temperature coefficient is the sum of the individual units.
· 50/60 Hz only.
Use Existing 2558 Programs
The 2558A is backwardly compatible with the previous 2558 Model. The new 2558A supports a 2558 command mode, which means that you can switch from the 2558 to the 2558A without modifying your program. It is also possible to mix 2558s and new 2558As in the same system.
Comparison with the 2558
|
|
2558A |
2558 |
AC Voltage |
Output range of the specified accuracy |
1.00 mV to 1200.0 V |
1.00 mV to 1200.0 V |
Accuracy (50/60 Hz) |
+/- 400 ppm |
+/- 950 ppm |
|
Frequency of the specified accuracy |
40 to 1000 Hz |
50 /60 /400 Hz |
|
AC Current |
Output range of the specified accuracy |
1.00 mA to 60.00 A |
1.00 mA to 60.00 A |
Accuracy (50/60 Hz) |
+/- 500 ppm |
+/- 950 ppm |
|
Frequency of the specified accuracy |
40 to 1000 Hz |
50 /60 /400 Hz |
|
Frequency |
Output range |
40 to 1000 Hz |
40 to 500 Hz |
Accuracy |
+/- 50 ppm |
+/- 1% |
|
Max. Output |
Approx. 36 VA (60 A/0.6 V) |
Approx. 36 VA (60 A/0.6 V) |
|
Stability |
+/- (20 ppm of setting + 30 ppm of range)/h |
+/- (0.03% of range)/h |
|
Dimensions (mm) |
426 (W) x 132 (H) x 400 (D) |
439 (W) x 149 (H) x 415 (D) |
SPECIFICATION
Front of Unit Specifications
Back of Unit Specifications
Output
Range |
Output Range |
Specified Output Range* |
Resolution |
Maximum Output |
100 mV |
0 to 144.00 mV |
1 to 120.00 mV |
10 uV |
--- |
1 V |
0 to 144.00 mV |
0.01 to 1.2000 V |
100 uV |
0.5 A or more |
10 V |
0 to 14.400 V |
0.1 to 12.000 V |
1 mV |
Approx. 3 A |
100 V |
0 to 144.00 V |
1 to 120.00 V |
10 mV |
Approx. 0.3 A |
300 V |
0 to 432.0 V |
3 to 360.0 V |
100 mV |
Approx. 0.1 A |
1000 V |
0 to 1440.0 V |
10 to 1200.0 V |
100 mV |
Approx. 6 mA |
100 mA |
0 to 144.00 mA |
1 to 120.00 mA |
10 uA |
Approx. 15 V |
1 A |
0 to 1.4400 A |
0.01 to 1.2000 A |
100 uA |
Approx. 15 V |
10 A |
0 to 14.400 A |
0.1 to 12.000 A |
1 mA |
Approx. 3 V |
50 A |
0 to 72.00 A |
0.5 to 60.00 A |
10 mA |
Approx. 0.6 V |
* 1% to 144% of range when frequency is 50 or 60 Hz.
Accuracy
|
Upper: 180 Days Lower: 1 Year |
|||||
|
10 % to 120% of range |
1% to 10% of range |
||||
|
+/- (% of setting + % of range) |
+/- (% of range) |
||||
Range |
50/60 Hz |
40 Hz ≤ f ≤ 400 Hz |
400 Hz |
50/60 Hz |
40 Hz ≤ f ≤ 400 Hz |
400 Hz |
100 mV |
0.03 + 0.01* 0.04 + 0.01* |
0.05 + 0.01 0.06 + 0.01 |
0.10 + 0.02 0.11 + 0.02 |
0.013 0.014 |
0.015 0.016 |
0.030 0.031 |
1 V |
||||||
10 V |
||||||
100 V |
||||||
300 V |
||||||
1000 V |
||||||
100 mA |
0.04 + 0.01* 0.055 + 0.01* |
0.06 + 0.01 0.075 + 0.01 |
0.12 + 0.02 0.135 + 0.02 |
0.014 0.0155 |
0.016 0.0175 |
0.032 0.0335 |
1 A |
||||||
10 A |
||||||
50 A |
* Add 0.1% of range when output is 120% to 144% of range.
첨부 (Attach)
파일내용 (The content of file) :
-. User's Manual (사용설명서) :
-. Brochure (브로셔) :
-. User's Manual(Simple Adjustment Procedure for voltage, current and Frequency) :
사진 (Picture) :
'사용설명서' 카테고리의 다른 글
B&K (Brüel & Kjær) / 2250_SOUND LEVEL METER / ANALYZER (0) | 2020.07.23 |
---|---|
BENETECH / GM1352_Sound Level Meter (0) | 2020.07.23 |
Tektronix / TDS1000 and TDS2000 Series_Oscilloscopes (0) | 2020.07.22 |
EZ Digital(LG) / FG-7005C_Sweep / Function Generator (0) | 2020.07.21 |
GW Instek / AFG-2225_Arbitrary Function Generator (0) | 2020.07.21 |
기기명 (Instrument) : Oscilloscopes (오실로스코프; 파형측정기)
제작회사 (Manufacturer) : Tektronix (텍트로닉스)
형식 (Model) : TDS1000 and TDS2000 Series
(TDS1002 , TDS1012 , TDS2002 , TDS2012 , TDS2014 , TDS2022 , TDS2024 , TDS1001 , TDS2004)
세부내용 (Description) :
Features & Benefits
-. 40 MHz, 60 MHz, 100 MHz, and 200 MHz Bandwidths
-. Sample Rates up to 2 GS/s
-. 2, or 4 Channels
-. Color, or Monochrome LCD Display
-. CompactFlash Mass Storage Option with TDS2MEM Module
-. Autoset Menu with Waveform Selection
-. Probe Check Wizard To Ensure Correct Probe Usage
-. Context-sensitive Help
-. Dual Time Base
-. Advanced Triggers, including Pulse Width Trigger and Line-Selectable Video Trigger
-. 11 Automatic Measurements
-. Multi-language User Interface
-. Waveform and Setup Memories
-. FFT Standard on All Models
-. OpenChoice® Solutions Speed Documentation and Analysis of Measurement Results
- TDS2CMAX Communication Module
- TDS2MEM Storage Memory and Communication Module
- TDSPCS1 OpenChoice PC Communication Software
- WaveStar™ Software
- Integration with Third-party Software
Applications
-. Design and Debug
-. Education and Training
-. Manufacturing Test and Quality Control
-. Service and Repair
Characteristics
TDS1000 and TDS2000 Series Electrical Characteristics
|
TDS1001 |
TDS1002 |
TDS1012 |
TDS2002 |
TDS2004 |
TDS2012 |
TDS2014 |
TDS2022 |
TDS2024 |
Display (1/4 VGA LCD) |
Mono |
Mono |
Mono |
Color |
Color |
Color |
Color |
Color |
Color |
Bandwidth*1 |
40 MHz |
60 MHz |
100 MHz |
60 MHz |
60 MHz |
100 MHz |
100 MHz |
200 MHz |
200 MHz |
Channels |
2 |
2 |
2 |
2 |
4 |
2 |
4 |
2 |
4 |
External Trigger Input |
Present on all models |
||||||||
Sample Rate on each channel |
1.0 GS/s |
1.0 GS/s |
1.0 GS/s |
1.0 GS/s |
1.0 GS/s |
1.0 GS/s |
1.0 GS/s |
2.0 GS/s |
2.0 GS/s |
Record Length |
2.5 K points on all models |
||||||||
Vertical Resolution |
8-bits |
||||||||
Vertical Sensitivity |
2 mV to 5 V/div on all models with calibrated fine adjustment |
||||||||
DC Vertical Accuracy |
±3% on all models |
||||||||
Vertical Zoom |
Vertically expand or compress a live or stopped waveform |
||||||||
Max Input Voltage |
300 VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13 Vp-p AC at 3 MHz and above |
||||||||
Position Range |
2 mV to 200 mV/div ±2 V; >200 mV to 5 V/div ±50 V |
||||||||
BW Limit |
20 MHz for all models |
||||||||
Input Coupling |
AC, DC, GND on all models |
||||||||
Input Impedance |
1 MΩ in parallel with 20 pF |
||||||||
Time Base Range |
5 ns to 50 s/div |
5 ns to 50 s/div |
5 ns to 50 s/div |
5 ns to 50 s/div |
5 ns to 50 s/div |
5 ns to 50 s/div |
5 ns to 50 s/div |
2.5 ns to 50 s/div |
2.5 ns to 50 s/div |
Time Base Accuracy |
50 ppm |
||||||||
Horizontal Zoom |
Horizontally expand or compress a live or stopped waveform |
*1 Bandwidth is 20 MHz at 2 mV/div, all models.
Acquisition Modes
Peak Detect - High frequency, and random glitch capture. Captures glitches as narrow as 12 ns (typical) using acquisition hardware at all time/div settings from 5 µs/div to 50 s/div.
Sample - Sample data only.
Average - Waveform averaged, selectable: 4, 16, 64, 128.
Single Sequence - Use the Single Sequence button to capture a single triggered acquisition sequence at a time.
Trigger System (Main Only)
Trigger Modes - Auto, Normal, Single Sequence.
Trigger Types
Edge (rising or falling) - Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject.
Video - Trigger on all lines or individual line, odd/even or all fields from composite video, or broadcast standards (NTSC, PAL, SECAM).
Pulse Width (or Glitch) - Trigger on a pulse width less than, greater than, equal to, or not equal to a selectable time limit ranging from 33 ns to 10 s.
Trigger Source
2-channel models - CH1, CH2, Ext, Ext/5, AC Line.
4-channel models - CH1, CH2, CH3, CH4, Ext, Ext/5, AC Line.
Trigger View
Displays trigger signal while trigger view button is depressed.
Trigger Signal Frequency Readout
Provides a frequency readout of the trigger source.
Cursors
Types - Voltage, Time.
Measurements - [Δ]T, 1/[Δ]T (frequency), [Δ]V.
Measurement System
Automatic Waveform Measurements - Period, Frequency, +Width, –Width, Rise Time, Fall Time, Max, Min, Peak-to-Peak, Mean, Cycle RMS.
Waveform Processing
Operators - Add, Subtract, FFT.
FFT - Windows: Hanning, Flat Top, Rectangular; 2048 sample points.
Sources - 2-channel models: CH1 - CH2, CH2 - CH1, CH1 + CH2.
4-channel models: CH1 - CH2, CH2 - CH1, CH3 - CH4, CH4 - CH3, CH1 + CH2, CH3 + CH4.
Autoset Menu - Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems, with undo autoset.
Autoset Menu for Multiple Signal Types
Signal Type |
Autoset Menu Choices |
Square Wave |
Single-cycle, Multi-cycle, Rising or Falling Edge |
Sine Wave |
Single-cycle, Multi-cycle, FFT Spectrum |
Video (NTSC, PAL, SECAM) |
Field: All, Odd, or Even Line: All, or Selectable Line Number |
I/O Interface
I/O interface |
TDS2CMAX Communications Module |
TDS2MEM Storage Memory and Communication Module |
Compatibility |
TDS200, TDS1000, TDS2000 Series Oscilloscopes |
TDS1002, TDS1012, TDS2002, TDS2012, TDS2014, TDS2022, TDS2024 Oscilloscopes*1 |
Printer Port |
Centronics-type Parallel |
|
Printer Capability (Requires Module) |
Graphics File Formats – TIFF, PCX (PC Paint Brush), BMP (Microsoft Windows), EPS (Encapsulated Postscript) and RLE |
|
Printer Formats – Bubble Jet, DPU-411, DPU-412, DPU-3445, Thinkjet, Deskjet, Laser Jet, Epson Dot (9- or 24-pin)*2, Epson C60*2, Epson C80 |
||
Layout – Landscape and Portrait |
||
RS-232 Programmability |
Full talk/listen modes. Control of all modes, settings and measurements. Baud rate up to 19,200. 9-pin DTE RS-232 Cable (012-1651-00) included |
|
GPIB (IEEE std. 488-1987) Programmability |
Full talk/listen modes. Control of all modes, settings, and measurements. |
Not Available |
Mass Storage CompactFlash Memory |
Not Available |
• Type 1 CompactFlash memory card supplied with Module*3. • Accepts any Type 1 CompactFlash card, up to and including 1 GB • Built-in Clock/Calendar • Includes CompactFlash to USB Memory Card Reader for use with Personal Computer |
OpenChoice® PC Communications Software |
• TDSPCS1 OpenChoice PC Communications Software included with each Module • Seamless connection from oscilloscope to PC through GPIB and RS-232 • Transfer and save settings, waveforms, measurements, and screen images • Includes a Windows desktop data transfer application in addition to convenient Microsoft Word and Excel Toolbar Add-ins |
*1 Not compatible with TDS1001, or TDS2004
*2 Requires instrument firmware version 2.12/4.12 or higher to support Epson C60/C80 printer formats.
*3 Supplied Type 1 CompactFlash memory card storage capacity 8 MB or greater.
Nonvolatile Storage
Nonvolatile Storage |
Standard |
Optional TDS2MEM Storage Memory and Communication Module*4 |
|
Reference Waveform Display |
Two 2500 point reference waveforms |
Same as instrument |
|
Waveform Storage |
2 Channel Models Two 2500 point reference waveforms |
4 Channel Models Four 2500 point reference waveforms |
96 or more reference waveforms per 8 MB |
Setups |
10 front panel setups |
4000 or more front panel setups per 8 MB |
|
Screen Images |
N/A |
128 or more screen images per 8 MB (the number of images depends on file format selected) |
|
Save All |
N/A |
12 or more Save All operations per 8 MB. A single Save All operation creates 2 to 9 files (setup, image, plus one file for each displayed waveform) |
*4 Supplied with Type 1 CompactFlash memory card, storage capacity 8 MB or greater.
Display Characteristics
Display -
Monochrome models: 1/4 VGA, backlit passive LCD with adjustable multi-level contrast and inverse video selectable from front panel.
Color models: 1/4 VGA, passive color LCD with color on black background with adjustable multi-level contrast.
Interpolation - Sin(x)/x.
Display Types - Dots, vectors.
Persistence - Off, 1 sec, 2 sec, 5 sec, infinite.
Format - YT and XY.
Environmental and Safety
Temperature -
Operating: 0 °C to +50 °C.
Nonoperating: –40 °C to +71 °C.
Humidity -
Operating and Nonoperating: up to 90% RH at or below +30 °C.
Operating: up to 60% RH up to 50 °C.
Nonoperating: up to 60% RH up to 55 °C.
Altitude -
Operating and Nonoperating: up to 3,000 m.
Electromagnetic Compatibility - Meets Directive 89/336/EEC, amended by 93/68/EEC, meets or exceeds EN55011 Class A Radiated and Conducted Emissions; FCC 47 CFR, Part 15, Subpart B, Class A; Australian EMC Framework, demonstrated per Emission Standard AS/NZS 2064; Russian GOST EMC regulations.
Safety - UL61010-1, CSA61010-1, IEC61010-1, EN61010-1.
Physical Characteristics
INSTRUMENT |
||
Dimensions |
mm |
in. |
Weight |
kg |
lbs. |
INSTRUMENT SHIPPING |
||
Package Dimensions |
mm |
in. |
RM2000 RACKMOUNT |
||
Dimensions |
mm |
in. |
Width |
323.8 |
12.75 |
Height |
151.4 |
5.96 |
Depth |
124.5 |
4.90 |
Instrument only |
2.0 |
4.4 |
with accessories |
2.2 |
4.9 |
Width |
476.2 |
18.75 |
Height |
266.7 |
10.50 |
Depth |
228.6 |
9.00 |
Width |
482.6 |
19.00 |
Height |
177.8 |
7.00 |
Depth |
108.0 |
4.25 |
첨부 (Attach)
파일내용 (The content of file) :
-. Data Sheet (데이터 시트) :
-. User Manual (사용자 설명서) :
-. Service Manual (서비스 매뉴얼) :
-. Operating Training Kit Manual :
-. Supplement (User Manual Specification Update) :
사진 (Picture) :
'사용설명서' 카테고리의 다른 글
BENETECH / GM1352_Sound Level Meter (0) | 2020.07.23 |
---|---|
YOKOGAWA / 2558A_AC Voltage Current Standard (0) | 2020.07.22 |
EZ Digital(LG) / FG-7005C_Sweep / Function Generator (0) | 2020.07.21 |
GW Instek / AFG-2225_Arbitrary Function Generator (0) | 2020.07.21 |
Keysight (Agilent) / E3634A_벤치 전원 공급기 (0) | 2020.07.21 |