사용설명서 2020. 7. 23. 10:44

기기명 (Instrument) :  Sound Level Meter

제작회사 (Manufacturer) :  BENETECH

형식 (Model) :  GM1352

세부내용 (Description) : 

About the product
1. Small and portable
2. Can be used for measurement of noise engineering, quality control, health prevention and environmental noise
3. Suitable for factories, offices, families, and etc
4. Powered by 3 x 1.5V AAA batteries

Features
1. Measuring range: 30-130 dBA
2. Accuracy: +-1.5dB
3. Frequency response: 31.5Hz-8000Hz
4. Frequency weighting feature: A weighting
5. Resolution: 0.1dB
6. Operating temperature: 0 - 40 celsius degree, 10%-80% relative humidity
7. Storage temperature: -20 - 60 celsius degree, 0-90% relative humidity
8. Min/Max/lock current value
9. LCD backlight
10. Manual/auto power off

Specification:

 

General

Model

GM1352

Size

155.6*49.6*26.6mm

Weight

82g

Package Weight

One Package Weight

0.16kgs / 0.34lb

Qty per Carton

20

Carton Weight

4.00kgs / 8.82lb

Carton Size

53cm * 33cm * 23cm / 20.87inch * 12.99inch * 9.06inch

Loading Container

20GP: 662 cartons * 20 pcs = 13240 pcs
40HQ: 1538 cartons * 20 pcs = 30760 pcs

 

 

 

 

첨부 (Attach)

   파일내용 (The content of file) : 

     -. Instruction Manual (사용설명서) :

BENETECH GM1352_Instruction Manual.pdf
1.24MB

   사진 (Picture)  :

BENETECH / GM1352

posted by 엠씨고
:
사용설명서 2020. 7. 22. 15:55

기기명 (Instrument) :  AC Voltage Current Standard (교류 전압 전류 교정기)

제작회사 (Manufacturer) :  YOKOGAWA (요꼬가와)

형식 (Model) :  2558A

세부내용 (Description) : 

The 2558A is a cost-effective, high-precision instrument capable of outputting a wide range of AC voltages and currents for the calibration of AC measurement devices such as analog wattmeters, power meters, clamp-on testers, and current transformers. Intuitive front panel controls and various computer interfaces enable the 2558A to be operated manually or become integrated into an larger system.

FEATURES

The 2558A AC Voltage Current Standard offers users the best-in-class functionality and reliability customers have come to trust from Yokogawa. 

A suite of features for verification and testing of AC measuring devices

·         Voltage, Current, and Frequency sweeping 

·         Output Divider

·         Direct Readout of the Deviation

·         Digital Display of Output

·         Common Current Output Terminals

Go beyond conventional accuracy and output standards

The wide output ranges of 1.00 mV to 1200.0 V AC and 1.00 mA to 60.00 A AC mean that the 2558A is the instrument of choice for the cost effective calibration of AC analog meters. Rotary controls and a range of computer interfaces enable the 2558A to be intuitively operated through the frontpanel or controlled by an ATE system.

 

High Accuracy

AC Voltage: +/- 0.04 %
AC Current: +/- 0.05 %

The 2558A AC Voltage Current Standard is more than sufficient to calibrate meters with a class 0.1 % accuracy.

10 to 120 % of range

+/- (% of setting + % of range)

 

50/60 Hz

40 ≤ f ≤ 400 Hz

400

AC Voltage

0.03 + 0.01*

0.05 + 0.01

0.10 + 0.02

AC Current

0.04 + 0.01*

0.06 + 0.01

0.12 + 0.02

* Add 0.1% of range when output is 120% to 144%.

 

1 to 10% of range

+/- (% of range)

 

50/60 Hz

40 ≤ f ≤ 400 Hz

400

AC Voltage

0.013

0.015

0.03

AC Current

0.014

0.016

0.032

 

High Stability

AC Voltage/Current: +/- 50 ppm/h

+/- (20 ppm of range + 30 ppm of range)/h

Perform measurements with high repeatability over time

Wide Output Range

AC Voltage: 1.00 mV to 1200.0 V 
AC Current: 1.00 mA to 60.00 A

6 voltage ranges (100 m/1/10/100/300/1000 ([V]))
4 current ranges (100 m/1/10/50 ([A]))

The generation range is 0 to 144 % of range

Wide Frequency Range

40 to 1000 Hz (Frequency accuracy: +/- 50 ppm)

The 2558A provides fixed frequencies of 50/60 Hz (commercial) and 400 Hz (marine and aviation), as well as variable frequencies from 40 to 1000 Hz.

The high frequency accuracy of the 2558A (50 ppm) also enables it to be used to calibrate frequency meters.

Multiple 2558A units can be synchronized using the internal phase shifter. This means that two 2558As can be used as accurate sources of voltage and current for calibrating power meters.

 

APPLICATION

Calibration & Meter Testing

The 2558A provides specific functions to enable meters to be calibrated accurately and efficiently.

Using the output divider and deviation

Calibrating two or more points is quick and simple. It is only necessary to preselect the number of required calibration points with the lower divider control and then use the upper control to step the output to the next calibration point. The deviation settings will then enable the output value and error of each calibration point to be displayed directly.

 

The deviation preset control can be used to move the output value in small increments (2 or 5 % of the step between calibration points).

This means that it is possible to finely approach the target calibration point, either from a lower value or a higher one, without exceeding it. This is particularly useful when the friction (hysteresis) of the moving part needs to be taken into consideration. In this case, the point is calibrated twice, once from a lower value and once more from a higher value and the final calibration result is the average of the two.

 

Using sweep

Needle sticking tests can be performed with high repeatability. It is possible to stop at any point and sweep around it in fine detail.

 

Power Calibration

A power calibration system can be created by using two 2558As (one each for AC voltage and AC current) together with a Yokogawa WT3000 power analyzer as the reference.

One of the 2558As acts as the master unit and provides the synchronizing oscillator signal. The required power factors is set by adjusting the phase shifter on the slave unit and monitoring the result on the WT3000. A 3 phase power calibrator system can be simply built by adding further 2558As.

 

Higher Current Output

To generate higher current than 72 A, two 2558As can be connected to double the output to 144 A.

Condition:

·         Accuracy, stability, temperature coefficient is the sum of the individual units.

·         50/60 Hz only.

 

 

Use Existing 2558 Programs

The 2558A is backwardly compatible with the previous 2558 Model. The new 2558A supports a 2558 command mode, which means that you can switch from the 2558 to the 2558A without modifying your program. It is also possible to mix 2558s and new 2558As in the same system.

 

Comparison with the 2558

 

 

2558A

2558

AC Voltage

Output range of the specified accuracy

1.00 mV to 1200.0 V

1.00 mV to 1200.0 V

Accuracy (50/60 Hz)

+/- 400 ppm

+/- 950 ppm

Frequency of the specified accuracy

40 to 1000 Hz

50 /60 /400 Hz

AC Current

Output range of the specified accuracy

1.00 mA to 60.00 A

1.00 mA to 60.00 A

Accuracy (50/60 Hz)

+/- 500 ppm

+/- 950 ppm

Frequency of the specified accuracy

40 to 1000 Hz

50 /60 /400 Hz

Frequency

Output range

40 to 1000 Hz

40 to 500 Hz

Accuracy

+/- 50 ppm

+/- 1%

Max. Output

Approx. 36 VA (60 A/0.6 V)

Approx. 36 VA (60 A/0.6 V)

Stability

+/- (20 ppm of setting + 30 ppm of range)/h

+/- (0.03% of range)/h

Dimensions (mm)

426 (W) x 132 (H) x 400 (D)

439 (W) x 149 (H) x 415 (D)

 

SPECIFICATION

Front of Unit Specifications

 

Back of Unit Specifications

 

Output

Range

Output Range

Specified Output Range*

Resolution

Maximum Output

100 mV

0 to 144.00 mV

1 to 120.00 mV

10 uV

---

1 V

0 to 144.00 mV

0.01 to 1.2000 V

100 uV

0.5 A or more

10 V

0 to 14.400 V

0.1 to 12.000 V

1 mV

Approx. 3 A

100 V

0 to 144.00 V

1 to 120.00 V

10 mV

Approx. 0.3 A

300 V

0 to 432.0 V

3 to 360.0 V

100 mV

Approx. 0.1 A

1000 V

0 to 1440.0 V

10 to 1200.0 V

100 mV

Approx. 6 mA

100 mA

0 to 144.00 mA

1 to 120.00 mA

10 uA

Approx. 15 V

1 A

0 to 1.4400 A

0.01 to 1.2000 A

100 uA

Approx. 15 V

10 A

0 to 14.400 A

0.1 to 12.000 A

1 mA

Approx. 3 V

50 A

0 to 72.00 A

0.5 to 60.00 A

10 mA

Approx. 0.6 V

* 1% to 144% of range when frequency is 50 or 60 Hz.

Accuracy

 

Upper: 180 Days

Lower: 1 Year

 

10 % to 120% of range

1% to 10% of range

 

+/- (% of setting + % of range)

+/- (% of range)

Range

50/60 Hz

40 Hz ≤ f ≤ 400 Hz

400 Hz

50/60 Hz

40 Hz ≤ f ≤ 400 Hz

400 Hz

100 mV

0.03 + 0.01*

0.04 + 0.01*

0.05 + 0.01

0.06 + 0.01

0.10 + 0.02

0.11 + 0.02

0.013

  0.014

0.015

0.016

0.030

0.031

1 V

10 V

100 V

300 V

1000 V

100 mA

0.04 + 0.01*

0.055 + 0.01*

0.06 + 0.01

0.075 + 0.01

0.12 + 0.02

0.135 + 0.02

0.014

0.0155

0.016

0.0175

0.032

0.0335

1 A

10 A

50 A

* Add 0.1% of range when output is 120% to 144% of range.

 

 

 

첨부 (Attach)

   파일내용 (The content of file) : 

     -. User's Manual (사용설명서) :

Yokogawa 2558A_User's Manual.pdf
4.73MB

     -. Brochure (브로셔) :

Yokogawa 2558A_Brochure.pdf
3.20MB

     -. User's Manual(Simple Adjustment Procedure for voltage, current and Frequency) :

Yokogawa 2558A_User's Manual(Simple Adjustment Procedure for voltage, current and Frequency).pdf
0.46MB

   사진 (Picture)  :

Yokogawa / 2558A

posted by 엠씨고
:
사용설명서 2020. 7. 22. 15:38

기기명 (Instrument) :  Oscilloscopes (오실로스코프; 파형측정기)

제작회사 (Manufacturer) :  Tektronix (텍트로닉스)

형식 (Model) :  TDS1000 and TDS2000 Series

(TDS1002 , TDS1012 , TDS2002 , TDS2012 , TDS2014 , TDS2022 , TDS2024 , TDS1001 , TDS2004)

세부내용 (Description) : 

Features & Benefits
 -. 40 MHz, 60 MHz, 100 MHz, and 200 MHz Bandwidths
 -. Sample Rates up to 2 GS/s
 -. 2, or 4 Channels
 -. Color, or Monochrome LCD Display
 -. CompactFlash Mass Storage Option with TDS2MEM Module
 -. Autoset Menu with Waveform Selection
 -. Probe Check Wizard To Ensure Correct Probe Usage
 -. Context-sensitive Help
 -. Dual Time Base
 -. Advanced Triggers, including Pulse Width Trigger and Line-Selectable Video Trigger
 -. 11 Automatic Measurements
 -. Multi-language User Interface
 -. Waveform and Setup Memories
 -. FFT Standard on All Models
 -. OpenChoice® Solutions Speed Documentation and Analysis of Measurement Results
    - TDS2CMAX Communication Module
    - TDS2MEM Storage Memory and Communication Module
    - TDSPCS1 OpenChoice PC Communication Software
    - WaveStar™ Software
    - Integration with Third-party Software

Applications
 -. Design and Debug
 -. Education and Training
 -. Manufacturing Test and Quality Control
 -. Service and Repair

 

Characteristics

TDS1000 and TDS2000 Series Electrical Characteristics

   

TDS1001

TDS1002

TDS1012

TDS2002

TDS2004

TDS2012

TDS2014

TDS2022

TDS2024

Display (1/4 VGA LCD)

Mono

Mono

Mono

Color

Color

Color

Color

Color

Color

Bandwidth*1

40 MHz

60 MHz

100 MHz

60 MHz

60 MHz

100 MHz

100 MHz

200 MHz

200 MHz

Channels

2

2

2

2

4

2

4

2

4

External Trigger Input

Present on all models

Sample Rate on each channel

1.0 GS/s

1.0 GS/s

1.0 GS/s

1.0 GS/s

1.0 GS/s

1.0 GS/s

1.0 GS/s

2.0 GS/s

2.0 GS/s

Record Length

2.5 K points on all models

Vertical Resolution

8-bits

Vertical Sensitivity

2 mV to 5 V/div on all models with calibrated fine adjustment

DC Vertical Accuracy

±3% on all models

Vertical Zoom

Vertically expand or compress a live or stopped waveform

Max Input Voltage

300 VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13 Vp-p AC at 3 MHz and above

Position Range

2 mV to 200 mV/div  ±2 V; >200 mV to 5 V/div  ±50 V

BW Limit

20 MHz for all models

Input Coupling

AC, DC, GND on all models

Input Impedance

1 MΩ in parallel with 20 pF

Time Base Range

5 ns to 50 s/div

5 ns to 50 s/div

5 ns to 50 s/div

5 ns to 50 s/div

5 ns to 50 s/div

5 ns to 50 s/div

5 ns to 50 s/div

2.5 ns to 50 s/div

2.5 ns to 50 s/div

Time Base Accuracy

50 ppm

Horizontal Zoom

Horizontally expand or compress a live or stopped waveform

*1 Bandwidth is 20 MHz at 2 mV/div, all models.

Acquisition Modes

Peak Detect - High frequency, and random glitch capture. Captures glitches as narrow as 12 ns (typical) using acquisition hardware at all time/div settings from 5 µs/div to 50 s/div.

Sample - Sample data only.

Average - Waveform averaged, selectable: 4, 16, 64, 128.

Single Sequence - Use the Single Sequence button to capture a single triggered acquisition sequence at a time.

Trigger System (Main Only)

Trigger Modes - Auto, Normal, Single Sequence.

Trigger Types

Edge (rising or falling) - Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject.

Video - Trigger on all lines or individual line, odd/even or all fields from composite video, or broadcast standards (NTSC, PAL, SECAM).

Pulse Width (or Glitch) - Trigger on a pulse width less than, greater than, equal to, or not equal to a selectable time limit ranging from 33 ns to 10 s.

Trigger Source

2-channel models - CH1, CH2, Ext, Ext/5, AC Line.

4-channel models - CH1, CH2, CH3, CH4, Ext, Ext/5, AC Line.

Trigger View

Displays trigger signal while trigger view button is depressed.

Trigger Signal Frequency Readout

Provides a frequency readout of the trigger source.

Cursors

Types - Voltage, Time.

Measurements - [Δ]T, 1/[Δ]T (frequency), [Δ]V.

Measurement System

Automatic Waveform Measurements - Period, Frequency, +Width, –Width, Rise Time, Fall Time, Max, Min, Peak-to-Peak, Mean, Cycle RMS.

Waveform Processing

Operators - Add, Subtract, FFT.

FFT - Windows: Hanning, Flat Top, Rectangular; 2048 sample points.

Sources - 2-channel models: CH1 - CH2, CH2 - CH1, CH1 + CH2.

4-channel models: CH1 - CH2, CH2 - CH1, CH3 - CH4, CH4 - CH3, CH1 + CH2, CH3 + CH4.

Autoset Menu - Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems, with undo autoset.

Autoset Menu for Multiple Signal Types

Signal Type

Autoset Menu Choices

Square Wave

Single-cycle, Multi-cycle, Rising or Falling Edge

Sine Wave

Single-cycle, Multi-cycle, FFT Spectrum

Video (NTSC, PAL, SECAM)

Field: All, Odd, or Even

Line: All, or Selectable Line Number

I/O Interface

I/O interface

TDS2CMAX Communications Module

TDS2MEM Storage Memory and Communication Module

Compatibility

TDS200, TDS1000, TDS2000 Series Oscilloscopes

TDS1002, TDS1012, TDS2002, TDS2012, TDS2014, TDS2022, TDS2024 Oscilloscopes*1

Printer Port

Centronics-type Parallel

Printer Capability (Requires Module)

Graphics File Formats – TIFF, PCX (PC Paint Brush), BMP (Microsoft Windows), EPS (Encapsulated Postscript) and RLE

Printer Formats – Bubble Jet, DPU-411, DPU-412, DPU-3445, Thinkjet, Deskjet, Laser Jet, Epson Dot (9- or 24-pin)*2, Epson C60*2, Epson C80

Layout – Landscape and Portrait

RS-232 Programmability

Full talk/listen modes. Control of all modes, settings and measurements.

Baud rate up to 19,200. 9-pin DTE

RS-232 Cable (012-1651-00) included

GPIB (IEEE std. 488-1987) Programmability

Full talk/listen modes. Control of all modes, settings, and measurements.

Not Available

Mass Storage CompactFlash Memory

Not Available

• Type 1 CompactFlash memory card supplied with Module*3.

• Accepts any Type 1 CompactFlash card, up to and including 1 GB

• Built-in Clock/Calendar

• Includes CompactFlash to USB Memory Card Reader for use with Personal Computer

OpenChoice® PC Communications Software

• TDSPCS1 OpenChoice PC Communications Software included with each Module

• Seamless connection from oscilloscope to PC through GPIB and RS-232

• Transfer and save settings, waveforms, measurements, and screen images

• Includes a Windows desktop data transfer application in addition to convenient Microsoft Word and Excel Toolbar Add-ins

*1 Not compatible with TDS1001, or TDS2004

*2 Requires instrument firmware version 2.12/4.12 or higher to support Epson C60/C80 printer formats.

*3 Supplied Type 1 CompactFlash memory card storage capacity 8 MB or greater.

Nonvolatile Storage

Nonvolatile Storage

Standard

Optional TDS2MEM Storage Memory and Communication Module*4

Reference Waveform Display

Two 2500 point reference waveforms

Same as instrument

Waveform Storage

2 Channel Models

Two 2500 point reference waveforms

4 Channel Models

Four 2500 point reference waveforms

96 or more reference waveforms per 8 MB

Setups

10 front panel setups

4000 or more front panel setups per 8 MB

Screen Images

N/A

128 or more screen images per 8 MB (the number of images depends on file format selected)

Save All

N/A

12 or more Save All operations per 8 MB. A single Save All operation creates 2 to 9 files (setup, image, plus one file for each displayed waveform)

*4 Supplied with Type 1 CompactFlash memory card, storage capacity 8 MB or greater.

Display Characteristics

Display -

Monochrome models: 1/4 VGA, backlit passive LCD with adjustable multi-level contrast and inverse video selectable from front panel.

Color models: 1/4 VGA, passive color LCD with color on black background with adjustable multi-level contrast.

Interpolation - Sin(x)/x.

Display Types - Dots, vectors.

Persistence - Off, 1 sec, 2 sec, 5 sec, infinite.

Format - YT and XY.

Environmental and Safety

Temperature -

Operating: 0 °C to +50 °C.

Nonoperating: –40 °C to +71 °C.

Humidity -

Operating and Nonoperating: up to 90% RH at or below +30 °C.

Operating: up to 60% RH up to 50 °C.

Nonoperating: up to 60% RH up to 55 °C.

Altitude -

Operating and Nonoperating: up to 3,000 m.

Electromagnetic Compatibility - Meets Directive 89/336/EEC, amended by 93/68/EEC, meets or exceeds EN55011 Class A Radiated and Conducted Emissions; FCC 47 CFR, Part 15, Subpart B, Class A; Australian EMC Framework, demonstrated per Emission Standard AS/NZS 2064; Russian GOST EMC regulations.

Safety - UL61010-1, CSA61010-1, IEC61010-1, EN61010-1.

Physical Characteristics

INSTRUMENT

Dimensions

mm

in.

Weight

kg

lbs.

INSTRUMENT SHIPPING

Package Dimensions

mm

in.

RM2000 RACKMOUNT

Dimensions

mm

in.

Width

323.8

12.75

Height

151.4

5.96

Depth

124.5

4.90

Instrument only

2.0

4.4

with accessories

2.2

4.9

Width

476.2

18.75

Height

266.7

10.50

Depth

228.6

9.00

Width

482.6

19.00

Height

177.8

7.00

Depth

108.0

4.25

 

 

첨부 (Attach)

   파일내용 (The content of file) : 

     -. Data Sheet (데이터 시트) :

Tektronix TDS1000 & TDS2000 series_Data Sheet.pdf
0.19MB

     -. User Manual (사용자 설명서) :

Tektronix TDS1000 & TDS2000 series_User Manual.pdf
1.24MB

     -. Service Manual (서비스 매뉴얼) :

Tektronix TDS1000 & TDS2000 series_Service Manual.pdf
2.03MB

     -. Operating Training Kit Manual :

Tektronix TDS1000 & TDS2000 series_Operating Training Kit Manual.pdf
6.57MB

     -. Supplement (User Manual Specification Update) :

Tektronix TDS1000 & TDS2000 series_Supplement(User Manual Specification Update).pdf
0.10MB

   사진 (Picture)  :

Tektronix / TDS1000 and TDS2000 Series

posted by 엠씨고
: