기기명 (Instrument) : 20MHz 2-Channel Oscilloscope
제작회사 (Manufacturer) : Kenwood
형식 (Model) : CS-4125A
세부내용 (Description) :
20MHz/1mV, 2CH/2-Trace
-. High reliability with Kenwood Original Hibrid ICs
-. High-intensity CRT (12 kV) (with scale illumination)
-. Dynamic range with a headroom for accurate waveform display without distortion
-. High sensitivity of 1 mV/div (DC to 5 MHz)
-. Maximum sweep rate of 20 ns/div (x10 MAG)
-. FIX sync
-. One-touch TV sync
-. Convenient VERT mode
-. One-touch ALT/CHOP switching
-. X-Y Mode
-. Vertical axis signal output connector
-. Waveforms can be observed by applying intensity modulation.
-. Added or subtracted waveforms can be observed.
Description
The CS-4100A Series with excellent cost efficiency were created from a fusion of performance, reliability, operability and design, and realize general-purpose characteristics which can be used in a variety of observations and inspections ranging from very small to very large signals.
High reliability with Kenwood Original Hibrid ICs
High-intensity CRT (12 kV) (with scale illumination)
Large-aperture (150 mm) CRT with post stage acceleration (12 kV) displays bright and sharp waveforms. The internal graticule eliminates parallax in measurement and the scale illumination is convenient for picture shooting and observations under low light (the CS-4125A uses a 2 kV CRT and does not have the scale illumination.)
Dynamic range with a headroom for accurate waveform display without distortion
As the dynamic range with a headroom assures the linearity of displayed waveforms, waveforms can be displayed without distortion until the upper limit of the frequency band. The CS-4135A provides a wide frequency bandwidth from DC to 40 MHz (-3 dB) between 5 mV/div to 5 V/div while the CS-4125A provides DC to 20 MHz (-3 dB) with the same sensitivity.
High sensitivity of 1 mV/div (DC to 5 MHz)
The vertical axis sensitivity can be varied continually from 1 mV/div to 5 V/div with an attenuator. The 1 mV/div sensitivity is especially powerful in measuring very-low, complicated signals.
Maximum sweep rate of 20 ns/div (x10 MAG)
The sweep rate can be varied continually from 0.5 s/div to 0.2µs/div. The sweep magnification (x10 MAG) allows to magnify the time scale by 10 times with a one-touch operation so that a part of a complicated waveform can be observed in more detail.
FIX sync
The FIX sync function cuts off troublesome procedures for synchronization. Much of the preparation work can be omitted so that the measurement or inspection work can be started more quickly.
One-touch TV sync
The horizontal and vertical video signals can be observed with a one-touch operation. Stable synchronization is assured without the need of synchronizing operation.
Convenient VERT mode
The VERT mode switches the sweep triggering sources automatically according to the vertical axis mode. When the vertical axis mode is CH1, the CH1 signal becomes the trigger source, and the CH2 signal becomes the trigger source when the vertical axis mode is CH2. In ALT mode, CH1 and CH2 signals can be triggered independently even when they have different frequencies.
One-touch ALT/CHOP switching
The ALT and CHOP modes can be switched with a one-touch operation in the 2-phenomena mode. This is convenient in phase-related observation of waveforms.
X-Y Mode
Commences operation as an X-Y oscilloscope with CH1 as the Y-axis and CH2 as the X-axis.
Vertical axis signal output connector
As this connector outputs the input signal at a rate of 50 mV/div, connecting a frequency counter makes it possible to measure the frequency of a very low signal while observing its waveform.
Waveforms can be observed by applying intensity modulation.
Added or subtracted waveforms can be observed.
The trace inclination can be corrected with the front panel operation.
Relay-type attenuators with long life and excellent operability are used.
Manufacturer Specs
CRT |
|
Type |
150mm rectangular with internal graticule |
Accelerating voltage |
Approx. 2kV |
Effective area |
8×10 div. (1div=10mm) |
Vertical axis (Common for CH1, CH2) |
|
Operating modes |
CH1, CH2, ADD, ALT, and CHOP |
Sensitivity |
1mV/div to 5V/div |
Attenuator |
1-2-5 steps, 12 ranges, and fine adjustment |
Frequency response |
|
DC |
DC to 20MHz (-3dB) (5mV/div. to 5V/div.) |
AC |
10Hz to 20MHz (-3dB) (5mV/div. to 5V/div.) |
Input impedance |
1MΩ ±2%, Approx. 23pF |
Rise Time |
Approx. 17.5ns (20MHz) (5mV/div. to 5V/div.) |
Crosstalk |
Below -40dB (at 1kHz sine wave) |
Polarity inversion |
CH2 only |
Maximum input voltage |
800V p-p or 400V (DC AC peak) |
CHOP frequency |
Approx. 250kHz |
Horizontal axis (CH2 input) |
|
Operating modes |
Switch to X-Y on CH1 : Y-axis / CH2 : X-axis |
Sensitivity |
Same as CH2 vertical axis |
Input impedance |
Same as CH2 vertical axis |
Frequency response |
DC : DC to 500kHz (-3dB) |
X-Y phase difference |
Within 3 degrees at 50kHz |
Sweep |
|
Sweep time |
0.5µs/div. to 0.5s/div. ±3% (0.2µs/div. : UNCAL) |
Magnified sweep (×10MAG) |
×10, ±5% (0.2µs/div. : UNCAL) |
Linearity |
±3% (0.2µs/div:UNCAL) (×10MAG : ±5%, 20ns/div. : UNCAL) |
Triggering |
|
Trigger sources |
VERT, CH1, CH2, LINE and EXT |
Mode |
AUTO, NORM, FIX, TV-F and TV-L |
Trigger coupling |
AC, TV-F and TV-L |
External trigger |
|
Input impedance |
1MΩ, Approx. 23pF |
Maximum input voltage |
84V p-p or 42V (DC ACpeak) |
Calibration voltage |
1V p-p±3% (Square wave, 1kHz, positive polarity) |
Intensity modulation |
|
Input voltage |
TTL level (dark for positive voltage) |
Input impedance |
Approx. 5kΩ |
Frequency response |
DC to 3.5MHz |
Maximum input voltage |
84V p-p or 42V (DC AC peak) |
CH1 Signal output |
|
Output voltag |
Approx. 50mV/div. (loaded 50Ω) |
Output impedance |
Approx. 50Ω |
Frequency response |
100Hz to 10MHz (within ±3dB, loaded 50Ω) |
Trace rotation |
Enables trace rotation adjustment from front panel |
Environmental condition |
10°C to 35°C, 85% or less (temperature/humidity for characteristics in spec.) |
Operation conditon |
0°C to 40°C, 85% or less (temperature/humidity for operation) |
Power source |
100/120/220/230V AC ±10% (250V AC maximum), 50/60Hz |
Power consumption |
30W maximum |
Case dimensions |
290 (W)×150 (H)×390 (D) mm |
Maximum dimensions |
290 (W)×172 (H)×443 (D) mm |
Weight |
Approx. 6.6kg |
Accessories |
Instruction manual (1) / Probe (PC-54) (2) / Power cable (1) |
첨부 (Attach)
파일내용 (The content of file) :
-. Instruction Manual (사용자 설명서) :
-. Service Manual (서비스 매뉴얼) :
사진 (Picture) :
'사용설명서' 카테고리의 다른 글
Keysight (Agilent) / E3634A_벤치 전원 공급기 (0) | 2020.07.21 |
---|---|
Tektronix / AFG310, AFG320_Arbitrary Function Generators (0) | 2020.07.21 |
NIDEC-SHIMPO / DT-107A_(LED) Tachometer (0) | 2020.07.21 |
NIDEC-SHIMPO / DT-207LR_(LED) Tachometer (0) | 2020.07.21 |
Cropico (Seaward Group) 005, 006 & 008 series_Decade Resistance Boxes (0) | 2020.07.21 |
기기명 (Instrument) : Universal Counter (주파수 카운터/계수기)
제작회사 (Manufacturer) : KENWOOD
형식 (Model) : FC-757
세부내용 (Description) :
5 Hz to 175 MHz Universal Counter, 1 ppm
-. Variety of Measurement Items
-. Low-Pass Filter Provided
-. Attenuator Provided
-. Data Hold Function
-. Addition Counting Function
-. 4-Step Gate Time Setting and Automatic Decimal Position Select
-. Zero Blanking
-. Over Flow Indicator
-. Combination Tilt Stand/Carrying Handle
-. External Reference Frequency Input Terminal Provided
첨부 (Attach)
파일내용 (The content of file) :
-. Instruction Manual (사용설명서) :
사진 (Picture) :
'사용설명서' 카테고리의 다른 글
Fluke / 175, 177, 179_True-RMS 디지털 멀티미터 (0) | 2020.07.20 |
---|---|
UNI-T / UT61 Series_Modern Digital Multimeter (0) | 2020.07.20 |
EXTECH / 461893_Photo Tachometer (0) | 2020.07.17 |
HITACHI / V series_Oscilloscope (Compactscope) (0) | 2020.07.17 |
CENTER / 320_Sound Level Meter (소음계) (0) | 2020.07.17 |
기기명 (Instrument) : NTSC / PAL Color Pattern Generator
제작회사 (Manufacturer) : TEXIO KENWOOD
형식 (Model) : CG-951 (NTSC) / CG-952 (PAL)
세부내용 (Description) :
CG SERIES Color Pattern Generators NTSC Generator, S-Output, w/out RF output
The CG-951 (NTSC)/CG-952(PAL) are color pattern generator incorporating a 10-step staircase signal generator featuring variation of the luminance level of each step in addition to the generator of color bar crosshatch raster and other patterns required for adjustments and inspections of video equipment and color TV. Based on the CG-930 Series of color pattern generators highly approved with excellent cost efficiency the CG-951/CG-952 are provided with additional new functions such as a variable 10-step staircase signal generator RGB output and Y/C separate outputs. With its improved resolution the CG-951/CG-952 are also compatible with a wide range of modified patterns.
-. Variable 10-Step Staircase Generator Making For Easy Adjustment of the Gamma-Corrector Circuit of LCD Displays
-. Burst Signal ON/OFF with Any Pattern
-. Selection of 9 Raster Patterns
-. Setup 0%
-. EEPROM Memory
-. Composite Sync and Vertical Sync Outputs Provided as Standard
첨부 (Attach)
파일내용 (The content of file) :
-. Service Manual (서비스 매뉴얼) :
-. Kenwood Color Pattern Generator_Catalog :
사진 (Picture) :
'사용설명서' 카테고리의 다른 글
Keysight / 33500B and 33600A series_파형/함수 발생기 (0) | 2020.07.15 |
---|---|
HP / 5314A_Universal Counter (0) | 2020.07.15 |
Bird / 43_RF Wattmeter - The Industry Standard (0) | 2020.07.15 |
Monarch Instrument / NOVA-STROBE BAX, BBX_Battery Powered Stroboscopes (0) | 2020.07.15 |
Keysight / E4980A, E4980AL_Precision LCR Meter (20Hz ~ 2 MHz) (0) | 2020.07.15 |