사용설명서 2020. 7. 21. 14:47

기기명 (Instrument) :  20MHz 2-Channel Oscilloscope

제작회사 (Manufacturer) :  Kenwood

형식 (Model) :  CS-4125A

세부내용 (Description) : 

20MHz/1mV, 2CH/2-Trace

 -. High reliability with Kenwood Original Hibrid ICs
 -. High-intensity CRT (12 kV) (with scale illumination)
 -. Dynamic range with a headroom for accurate waveform display without distortion
 -. High sensitivity of 1 mV/div (DC to 5 MHz)
 -. Maximum sweep rate of 20 ns/div (x10 MAG)
 -. FIX sync
 -. One-touch TV sync
 -. Convenient VERT mode
 -. One-touch ALT/CHOP switching
 -. X-Y Mode
 -. Vertical axis signal output connector
 -. Waveforms can be observed by applying intensity modulation.
 -. Added or subtracted waveforms can be observed.

Description
The CS-4100A Series with excellent cost efficiency were created from a fusion of performance, reliability, operability and design, and realize general-purpose characteristics which can be used in a variety of observations and inspections ranging from very small to very large signals.

High reliability with Kenwood Original Hibrid ICs

High-intensity CRT (12 kV) (with scale illumination)
Large-aperture (150 mm) CRT with post stage acceleration (12 kV) displays bright and sharp waveforms. The internal graticule eliminates parallax in measurement and the scale illumination is convenient for picture shooting and observations under low light (the CS-4125A uses a 2 kV CRT and does not have the scale illumination.)

Dynamic range with a headroom for accurate waveform display without distortion
As the dynamic range with a headroom assures the linearity of displayed waveforms, waveforms can be displayed without distortion until the upper limit of the frequency band. The CS-4135A provides a wide frequency bandwidth from DC to 40 MHz (-3 dB) between 5 mV/div to 5 V/div while the CS-4125A provides DC to 20 MHz (-3 dB) with the same sensitivity.

High sensitivity of 1 mV/div (DC to 5 MHz)
The vertical axis sensitivity can be varied continually from 1 mV/div to 5 V/div with an attenuator. The 1 mV/div sensitivity is especially powerful in measuring very-low, complicated signals.

Maximum sweep rate of 20 ns/div (x10 MAG)
The sweep rate can be varied continually from 0.5 s/div to 0.2µs/div. The sweep magnification (x10 MAG) allows to magnify the time scale by 10 times with a one-touch operation so that a part of a complicated waveform can be observed in more detail.

FIX sync
The FIX sync function cuts off troublesome procedures for synchronization. Much of the preparation work can be omitted so that the measurement or inspection work can be started more quickly.

One-touch TV sync
The horizontal and vertical video signals can be observed with a one-touch operation. Stable synchronization is assured without the need of synchronizing operation.

Convenient VERT mode
The VERT mode switches the sweep triggering sources automatically according to the vertical axis mode. When the vertical axis mode is CH1, the CH1 signal becomes the trigger source, and the CH2 signal becomes the trigger source when the vertical axis mode is CH2. In ALT mode, CH1 and CH2 signals can be triggered independently even when they have different frequencies.

One-touch ALT/CHOP switching
The ALT and CHOP modes can be switched with a one-touch operation in the 2-phenomena mode. This is convenient in phase-related observation of waveforms.

X-Y Mode
Commences operation as an X-Y oscilloscope with CH1 as the Y-axis and CH2 as the X-axis.

Vertical axis signal output connector
As this connector outputs the input signal at a rate of 50 mV/div, connecting a frequency counter makes it possible to measure the frequency of a very low signal while observing its waveform.

Waveforms can be observed by applying intensity modulation.

Added or subtracted waveforms can be observed.

The trace inclination can be corrected with the front panel operation.

Relay-type attenuators with long life and excellent operability are used.

Manufacturer Specs

CRT

Type

150mm rectangular with internal graticule

Accelerating voltage

Approx. 2kV

Effective area

8×10 div. (1div=10mm)

Vertical axis (Common for CH1, CH2)

Operating modes

CH1, CH2, ADD, ALT, and CHOP

Sensitivity

1mV/div to 5V/div
(1mV/div., 2mV/div.±5%, 5mV/div to 5V/div. ±3%)

Attenuator

1-2-5 steps, 12 ranges, and fine adjustment

Frequency response

DC

DC to 20MHz (-3dB) (5mV/div. to 5V/div.)
DC to 5MHz (-3dB) (1mV/div. to 2mV/div.)

AC

10Hz to 20MHz (-3dB) (5mV/div. to 5V/div.)
10Hz to 5MHz (-3dB) (1mV/div. to 2mV/div.)

Input impedance

1MΩ ±2%, Approx. 23pF

Rise Time

Approx. 17.5ns (20MHz) (5mV/div. to 5V/div.)
Approx. 70ns (5MHz) (1mV/div. to 2mV/div.)

Crosstalk

Below -40dB (at 1kHz sine wave)

Polarity inversion

CH2 only

Maximum input voltage

800V p-p or 400V (DC AC peak)

CHOP frequency

Approx. 250kHz

Horizontal axis (CH2 input)

Operating modes

Switch to X-Y on CH1 : Y-axis / CH2 : X-axis

Sensitivity

Same as CH2 vertical axis

Input impedance

Same as CH2 vertical axis

Frequency response

DC : DC to 500kHz (-3dB)
AC : 10Hz to 500kHz (-3dB)

X-Y phase difference

Within 3 degrees at 50kHz

Sweep

Sweep time

0.5µs/div. to 0.5s/div. ±3% (0.2µs/div. : UNCAL)
1-2-5 steps, 20 ranges, and fine adjustment

Magnified sweep (×10MAG)

×10, ±5% (0.2µs/div. : UNCAL)

Linearity

±3% (0.2µs/div:UNCAL) (×10MAG : ±5%, 20ns/div. : UNCAL)

Triggering

Trigger sources

VERT, CH1, CH2, LINE and EXT

Mode

AUTO, NORM, FIX, TV-F and TV-L

Trigger coupling

AC, TV-F and TV-L

 

External trigger

Input impedance

1MΩ, Approx. 23pF

Maximum input voltage

84V p-p or 42V (DC ACpeak)

Calibration voltage

1V p-p±3% (Square wave, 1kHz, positive polarity)

Intensity modulation

Input voltage

TTL level (dark for positive voltage)

Input impedance

Approx. 5kΩ

Frequency response

DC to 3.5MHz

Maximum input voltage

84V p-p or 42V (DC AC peak)

CH1 Signal output

Output voltag

Approx. 50mV/div. (loaded 50Ω)

Output impedance

Approx. 50Ω

Frequency response

100Hz to 10MHz (within ±3dB, loaded 50Ω)

Trace rotation

Enables trace rotation adjustment from front panel

Environmental condition

10°C to 35°C, 85% or less (temperature/humidity for characteristics in spec.)

Operation conditon

0°C to 40°C, 85% or less (temperature/humidity for operation)

Power source

100/120/220/230V AC ±10% (250V AC maximum), 50/60Hz

Power consumption

30W maximum

Case dimensions

290 (W)×150 (H)×390 (D) mm

Maximum dimensions

290 (W)×172 (H)×443 (D) mm

Weight

Approx. 6.6kg

Accessories

Instruction manual (1) / Probe (PC-54) (2) / Power cable (1)

 

 

첨부 (Attach)

   파일내용 (The content of file) : 

     -. Instruction Manual (사용자 설명서) :

KENWOOD CS-4125 CS-4135_Instruction Manual.pdf
3.13MB

     -. Service Manual (서비스 매뉴얼) :

KENWOOD CS-4125 CS-4135_Service Manual.pdf
5.81MB

   사진 (Picture)  :

Kenwood / CS-4125A

 

posted by 엠씨고
: